Orthofix - Always Innovating

Product Description

Angulation, translation and rotation. The Sheffield Ring Fixation System is a design achievement that advances the possibilities of limb reconstruction.

  • Unparalleled stability
  • Rapid assembly
  • Unlimited possibilities

The Sheffield System XWire has a unique helicoidal tip design that has been demonstrated to improve performance and ease of insertion.1 The XWire offers a new lateral olive design and is available in sizes 1.8 to 2.0 mm.

back to top

Indication
ACUTE TRAUMA
  • Tibial articular fractures: plateau and pilon
  • Tibial articular fractures with diaphyseal extension
  • High energy diaphyseal fractures of the tibia
  • Femoral fractures, particularly distal
  • Humeral fractures
LIMB RECONSTRUCTION
  • Correction of post-traumatic, acquired and congenital deformities: simple, juxta-articular, oblique plane, multiplanar. The Sheffield Ring Fixator is usually used in the lower limb for tibial and foot deformities, but is also useful for femoral and knee deformities. It may also be used in the upper limb, particularly the humerus
  • Arthrodesis: knee, ankle and subtalar joints
  • Limb Lengthening: monofocal and bifocal
  • Nonunion and bone loss:
    • Monofocal – compression, neutralization, distraction
    • Bifocal – bone transport, acute shortening, combined multifocal
  • Joint contracture in adults and children: knee, ankle and foot
  • Articulated distraction: ankle, foot and knee

back to top

Surgeon Benefits
  • Lightweight, radiolucent carbon fiber construction
  • Central slots allow multiple levels of wire fixation at higher tension
  • Circumferential grooves allow versatile wire placement
  • Two-thirds and one-third rings which may be joined as a full ring set to protect soft tissue, or allow wire placement at a wider angle
  • High strength construction with reinforced anterior section to support wire tension

back to top

Surgeon Support Materials
* Protected PDF files: You will not be able to copy or print.
Sheffield Ring Fixator Videos:

back to top

Clinical References:
  • The Sheffield Hybrid Fixator: Design Considerations and Clinical Experiences Full Text Article (PDF 106KB)
  • Drilling Efficiency and Temperature Elevation of Three Types of Kirschner-wire Point Full Text Article (PDF 205KB)

back to top

Patient Support Materials
* Protected PDF files: You will not be able to copy or print.

back to top

Part Reference Numbers
Part Reference No. Description
10012

3MM Polyhedral Allen Wrench

10017 6MM Polyhedral Allen Wrench
10038 Supplementary Screw Clamp
18001 Wire Tensioning Device
18002 K-Wire Guide
30017 5 mm Polyhedral Allen Wre
50008 Compression Distraction, Clicker, Std
50009 Compression Distraction, Clicker, Long
80025 Two Hole K-Wire Securing Pin
80031 Three Hole Slider Wire Clamp
80035 Sheffield Clamp
80041 Independent Wire Clamp
80042 50 mm Securing Post
80044 100 mm Securing Post
80047 Ball Jointed Connecting Rod
80074 Single Screw Clamp
80112 Lateral Olive K-Wire, 2X400
80123 Central Olive K-Wire, 2X450
80124 K-Wire, 2X450
80200 K-Wire Cover (20 Each)
81008 Ring Connecting Screw
81010 Translation/Rotation Hinge
81015 Hinge Clamp
81020 Extension Plate
81022A Nuts And Washers, (20 Each)
81023 Slotted Washer (10 Each)
81024 25 mm Bolt (10 Each)
81025 Counter Nuts
81030 Speed Wrench, 10 mm
81031 Open End Wrench, 10 mm
81036 80 mm Threaded Bars (3 Each)
81037 120 mm Threaded Bars (3 Each)
81038 160 mm Threaded Bars (3 Each)
81039 200 mm Threaded Bars (3 Each)
81043 Radiolucent Bar, 6 mm X 300 mm
81048 300 mm Threaded Bars (3 Each)
81049 400 mm Threaded Bars (3 Each)
91017 Universal Allen Wrench
91039 Supplementary Screw Holder Bar, Radiolucent
81150 Radiolucent 2/3 Ring, 150 mm Diameter
81150P Radiolucent 1/3 Ring, 150 mm Diameter
81175 Radiolucent 2/3 Ring, 175 mm Diameter
81175P Radiolucent 1/3 Ring, 175 mm Diameter
81190 Radiolucent 2/3 Ring, 190 mm Diameter
81190P Radiolucent 1/3 Ring, 190 mm Diameter
450109 Steri-Tray, Hybrid Instrument, Empty
450109C Sheffield Steri-Tray System
W1003 Wire Cutter
W2200 Olive Washer (4 Each)
Also Available:
81125 RS Carbon Ring
81125P RS Carbon Ring
81220 2/3 Carbon Fiber, 220 mm
81220P 1/3 Carbon Fiber, 220 mm

back to top

Web Resources
  1. Case Study: Limb Reconstruction with the Sheffield Ring Fixator (Dr. M. Saleh)
  2. www.limblengthening.com
  3. www.limblength.com
  4. www.fracturecarecenter.com
  5. www.joshuakaye.com
  6. www.chicagofootandanklesurgery.com
  7. www.acfas.org
  8. www.llrs.org/
  9. www.asami.org/

back to top

Footnotes
1 Piska, M., Yang, L., Reed M., Saleh, M. Drilling efficiency and temperature elevation of three types of Kirchner-wire point; JBJS 2002;84-B, 137-140

back to top

About Us | Investors | Innovation | Products | Scientific Area | Patient Support | Events | Careers | Contact Us

©2009 orthofix.com